MODEL |
PM-WCC-100AM-1248 |
ELECTRICAL |
Input Voltage Range (no damage) |
0 ~ 220 VAC |
Operating Input Voltage Range from PMG (Permanent Magnet Generator) |
20 ~ 220 VAC 0 ~ 600 Hz |
Optimal Range: 20 ~ 180 VAC |
System voltage ratings |
12, 24, 36, 48 VDC |
Current ratings-Battery Charge Control |
100A |
Max. Current in the Brake Resistor |
100A Diversion load |
DC Output Voltage Range |
16 ~ 240 VDC Operating |
240 VDC Maximum |
Automatic Brake Function |
5 Level: 200, 210, 220, 230, 240 VDC (Adjustable) Can be customized for the wind turbines |
Maximum Wind Turbine Capacity |
Charging 48 VDC Batteries |
6.0KW |
Charging 36 VDC Batteries |
4.5KW |
Charging 24 VDC Batteries |
3.0KW |
Charging 12 VDC Batteries |
1.5KW |
Charge Regulation Modes |
Bulk, Absorption, Float, Auto/ Manual Equalization |
Battery Temperature Compensation |
5.0 mV per °C , per 2 volt cell |
DC to DC Conversion Capability |
12V Battery: 16~240VDC |
24V Battery: 32~240VDC |
36V Battery: 48~240VDC |
48V Battery: 64~240VDC |
Display Status |
Built-in 2-line, 20-character LCD with backlight LCD status screen displays input voltage and current, output voltage and current, charge-mode, Battery SOC |
Data Logging |
Logs energy harvested for 90 days, LCD displays WH, KWH, AH |
Energy Monitor |
LCD shows SOC, AH, WH, and present charge or discharge current. A 50mV/ 500Amp shunt is required to use |
Auxiliary Relays |
Two independent relays with from A (SPST) contacts for control of external devices. Contact rating is 3 Amps, 50VDC |
Operation Temperature |
Full Power Output to +50 °C ambient |
Standby Power |
< 2 Watts |
Relative Humidity |
0 ~ 100% condensing |
MECHANICAL |
Dimensions (mm) [H x W x L] |
401 x 258 x 183 |
Weight |
8.3 kg |
Optional Diversion Load |
|